ArthroplastyCohort

Periprosthetic femoral fracture following primary hip arthroplasty

The Bone & Joint Journal · 1 Nov 2026

Rigour62/100
Clinical72/100
Priority47/100

Priority is the editorial-priority score. All scores are out of 100. Rigour is how well the study was done for its own design: 50 means nothing is known either way, and the design itself is not counted. Clinical is how far this paper should move patient care if its methods hold up: the most its design can claim, times the relevance of its question, times how clearly it answered. The size of a result is read only against a threshold the paper states itself.

Why it matters

Periprosthetic femoral fracture is a leading cause of reoperation after hip arthroplasty, and these data suggest stem choice may need to be tailored to the patient's sex, age, and frailty.

The evidence

This Norwegian registry study followed 204,041 primary hip replacements and hemiarthroplasties (2005 to 2025) to see how femoral stem design and fixation, analysed separately by sex and age, relate to reoperation for a fracture around the stem. Cemented composite beam stems (Lubinus SPII) had the lowest risk overall. In males, cemented polished taper-slip stems had about nine times the adjusted hazard compared with composite beam stems (aHRR 9.4, 95% CI 5.4 to 16.3), uncemented collarless stems were similar, and uncemented collared stems were about four times higher; age thresholds for increased risk differed by sex and stem type.

Reoperation for periprosthetic femoral fracture (males, PTS vs CB): Hazard ratio 9.4 (95% CI 5.4 to 16.3; ratio). Interpret in the study's stated comparison; this alone does not establish a treatment's causal effect.

How strong would a hidden confounder have to be? This comparison was not randomised. To explain the association away, something the study did not account for would need to be tied to both the exposure and the outcome by a risk ratio of about 18.29, and by about 10.27 to pull the interval back to no difference. This is the E-value. The estimate is an odds or hazard ratio read as a risk ratio, which overstates this when the outcome is common. It is shown for context and is not part of any score.

Why this rigour score?

Registry cohort (adjusted)Neutral starting point: 50, the same for every design

62/ 100

Raised the score

  • Competing risks handled+12.5
  • 97% registry capture+11.5

Lowered the score

  • Cases were selected rather than consecutive−15

Room left by what was not reported. 1 of 4 criteria that apply to this design could be assessed from the paper. Had the others been reported, rigour could sit anywhere from 49 to 69. This is not a confidence interval.

Methods at a glance

Recorded assessment
  • Confounding adjustmentNot applicable
  • Covariate balance confirmedNot applicable
  • Outcome assessors blindedNot reported
  • Comparable start of follow-upMet
  • Adequate statistical powerNot reported
  • Prospective registrationNot met

Not reported does not mean not done. Checks have different weights; this is not a count of boxes ticked. Statistical power is recorded here but is not a rigour criterion: it is read by the clinical score, where it decides how settled the answer is.

See the full score breakdown
Neutral starting point (every design)
50
97% registry capture
+11.5
Cases were selected rather than consecutive
−15
Competing risks handled
+12.5
Journal prior (not an observed method)
+3.4
Final rigour score rounded
62 / 100

Rigour is how well the study was done for its own design. Every design starts at 50, which means nothing is known either way; 100 means every safeguard that applies to this design was shown. The points above are already scaled by how much this design can show: a check counts for more in a design with few applicable checks and for less in one with many. The design itself is not counted here: it sets the ceiling of the clinical score instead. Points are shown to one decimal place; the final score uses unrounded values.

Checklist from the stored appraisal. “Not met” describes the recorded criterion; it does not always produce a deduction. This overview supports reading the full study.

How the clinical score was reached

The question: 9/9. Three judgements of how much it matters to patients, which decision it informs and how closely it fits their care.

Patient consequence: high (3/3). The primary outcome is itself a major, durable patient outcome: death, limb loss, permanent disability, reoperation or revision, a serious complication, or validated patient-reported function or pain at a time point that matters for the decision (usually a year or more after elective surgery). Reserve for clearly major outcomes; most papers do not qualify.

Decision relevance: high (3/3). The study compares the actual options a clinician chooses between (or a whole strategy), and its primary result directly indicates which to choose, or that they are interchangeable. A clinician could act on it without a further translation step.

Applicability: high (3/3). Typical patients for this decision, in the kind of setting where the decision is made (routine or specialist care), with the options delivered as they would be in practice. Rare and specialist conditions qualify when this holds. Multicentre recruitment alone does not make a study high.

What it found: Association shown (×1.00). The interval excludes no difference, but the groups were not randomised: this is an association, and the design ceiling limits how far it can count.

The design ceiling: 72. The most a registry cohort (adjusted) can score here, however relevant its question and clear its answer. The design is counted here and nowhere else; rigour does not include it.

Clinical = 72 × 9/9 × 1.00 = 72.

For journal club

1.For a 78-year-old man with a displaced femoral neck fracture, how would these findings influence whether you choose a cemented composite beam, a cemented polished taper-slip, or an uncemented collared stem?

2.If uncemented collared stems performed similarly to composite beam stems in younger, robust patients, how would you counsel a 60-year-old with osteoarthritis about stem options and fracture risk?

Original publication title

Periprosthetic femoral fracture following primary hip arthroplasty

Read original paper